Release Notes
Issue 36:
Description
URL string in iDRAC hardware inventory list displays incorrect https port number.
Resolution
IP URL in hardware inventory output always displays the standard https port number, that is, 443.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 37:
Description
Sometimes Virtual Console does not get enabled after iDRAC is reset.
Resolution
Toggle the Virtual Console option in the iDRAC web interface.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 38:
Description
When you update the rebrand image from the iDRAC web interface, the system reboots and the
rebranded images are applied successfully. During POST, if you press <F10>, the Lifecycle Controller UI
starts to launch. The progress bar displays till 90% and then the system starts rebooting.
Resolution
After rebranding, do not access the Lifecycle Controller UI.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 39:
Description
If the number of physical or virtual disks selected for identification is more than 100, the blink or unblink
operation fails without displaying any message.
Resolution
Select less than 100 physical or virtual disks, or the required disk and retry the operation.
Versions/ Systems Affected
All Dell PowerEdge systems with iDRAC8.
Issue 40:
Description
Chassis slots mapped to the server are not visible using the WS-MAN DCIM_Slot class enumeration.
DCIM_slot class provides the server hardware information in terms of available and occupied slots where
devices can be added or removed respectively.
Resolution
None
Versions/ Systems Affected
All Dell Modular PowerEdge systems with iDRAC8.