Reference Guide
rollback
Description Allows you to roll back the firmware to an earlier version.
Synopsis
racadm rollback <FQDD>
NOTE: To get the list of available rollback versions and FQDDs, run the racadm
swinventory command.
Input <FQDD>: Specify the FQDD of the device for which the rollback is required.
Example
racadm rollback iDRAC.Embedded.1-1
RAC1056: Rollback operation initiated successfully.
sensorsettings
Description Allows you to perform threshold settings of the sensor.
To run this subcommand, you must have Configure iDRAC privilege.
NOTE: An error message is displayed when the following is performed:
• A set operation is performed on an unsupported FQDD.
• Out of range settings is entered.
• Invalid sensor FQDD is entered.
• Invalid threshold level filter is entered.
Synopsis
racadm sensorsettings set <FQDD> -level Min <value>
Input
• <FQDD> — Sensor or corresponding sensor FQDD which needs a threshold
configuration. Run the command, racadm getsensorinfo to view the sensor
FQDD. The
R/W field in the output getsensorinfo indicates if the sensor thresholds
can be configured. Replace the <FQDD> field with the corresponding sensor FQDD
that needs a threshold configuration.
• -level — threshold level for the sensor setting. Values are Max or Min.
Examples To set the minimum noncritical threshold level for a power sensor type.
racadm sensorsettings set iDRAC.Embedded.1#SystemBoardCPUUsage -
level Max 95
NOTE: The entered value must be lesser or higher than the sensor critical threshold
limit.
serveraction
Description Enables you to perform power management operations on the blade system.
To run this subcommand, you must have the Execute Server Control Commands
permission.
Synopsis
racadm serveraction <action> -f
• racadm serveraction -a <action>
84