Storage.Controller.PossibleloadBalancedMode (Read or Write)
Description This attribute represents the ability to automatically use both controller ports connected
to the same enclosure to route I/O requests.
Legal Values
• Automatic
• Disabled
Default value Automatic
Write
Privilege
Server Control
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.RebuildRate (Read or Write)
Description
The Rebuild Rate is the percentage of the system's resources dedicated to rebuilding a
failed disk when a rebuild is necessary.
Legal Values Values: 0–100
Default value 100
Write
Privilege
Server Control
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.ReconstructRate (Read or Write)
Description
The Reconstruct Rate is the percentage of the system's resources dedicated to
reconstructing a disk group after adding a physical disk drive or changing the RAID level
of a virtual disk residing on the disk group.
Legal Values Values: 0–100
Default value 100
Write
Privilege
Server Control
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.RequestedControllerMode (Read or Write)
Description
Modifies the controller mode to RAID or HBA.
Legal Values
• None
• RAID