Reference Guide

To use this subcommand with the set and test option, you must have the
Administrator privilege.
Synopsis
racadm eventfilters <eventfilters command type>
racadm eventfilters get -c <alert category>
racadm eventfilters set -c <alert category> -a <action> -n
<notifications>
racadm eventfilters set -c <alert category> -a <action> -r
<recurrence>
racadm eventfilters test -i <Message ID to test>
NOTE: The general format of an alert category:
idrac.alert.category.[subcategory].[severity]
where, category is mandatory, but subcategory and severity are optional. A severity
cannot precede a subcategory.
Valid Category values are:
All
System
Storage
Updates
Audit
Config
Worknotes
Valid Severity values are:
Critical
Warning
Info
Valid examples of alert queries are:
idrac.alert.all
idrac.alert.audit
idrac.alert.audit.lic
idrac.alert.audit.warning
idrac.alert.audit.lic.critical
Input
get — Displays the list of eventfilter settings.
set — Configures the actions and notifications for a given eventfilter configuration.
-i — Message ID for which the simulation is needed.
-c — Alert category of the specific event filter.
-a — The action that must be invoked when the event occurs. Valid values are none,
powercycle, power off, or systemreset.
-n — The notification is sent when the event occurs. Valid values are all, snmp,
ipmi, ws-events, oslog, email, remotesyslog or none. You can append
multiple notifications separated by a comma. You cannot enter the values all or
none with other notifications. If incorrect notification is specified along with other
valid notifications, the valid and invalid notification set is failed.
31