Reference Guide

Default value 255 — None
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalSettings.BaseAlgorithm (Read or Write)
Description Specifies the thermal base algorithm.
NOTE: This object is not applicable for Rack and Tower server.
Legal Values
0 — Auto
1 — Max Exhaust Temperature
2 — Min Power
Default
values
None
License
Required
iDRAC Express
Dependency None
System.ThermalSettings.MinimumFanSpeed (Read or Write)
Description
Specifies the minimum fan speed required.
NOTE: This attribute is platform dependent.
Legal Values MFSMinimumLimit — MFSMaximumLimit
Default Value 0
Write
Privilege
Not Applicable
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalSettings.FanSpeedOffset (Read or Write)
Description
Specifies the fan speed offset.
NOTE: This attribute is platform dependent.
Legal Values
0 — Low fan speed
1 — High fan speed
255 — OFF
Default value OFF
License
Required
iDRAC Express or iDRAC Enterprise
237