Reference Guide

System.Location.Chassis.Slot (Read or Write)
Description
Indicates chassis slot.
Legal Values
Values: 1–255
Default Value Not Applicable
Write
Privilege
Configure iDRAC
License
Required
Not Applicable
Dependency
None
System.Power
This group provides power management features for iDRAC.
The following section provides information about the objects in this group.
NOTE: For Dell PowerEdge FM120x4 server with more than one iDRAC, the power is received and
shared from CMC. Hence, the information about power and temperature for individual iDRACs are
not displayed.
System.Power.Status (Read Only)
Description
Represents the device power state, either ON or OFF.
Legal Values
0 — Server is off
1 — Server is on.
Default Value
0 — Server is off
Write
Privilege
Not Applicable
License
Required
Not Applicable
Dependency Not Applicable
System.Power.ServerAllocation (Read Only)
Description
Indicates the power allocated to running blades. This value is displayed in both watts
and BTU/h units.
Legal Values
0–7928
Default Value Not Applicable
218