Reference Guide
System.Backplane.BackplaneBusMode (Read Only)
Description Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode.
Legal Values
• 0 — Unknown
• 1 — I2C
• 2 — SGPIO
Default Value 1 — I2C
Write
Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ChassisControl
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To
control the chassis related events, use this group.
System.ChassisControl.ChassisManagementMonitoring (Read or Write)
Description
Enables or disables the event forwarding from CMC.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default value 1 — Enabled
Write
Privilege
Server Control
License
Required
Base
Dependency ChassisMangamentAt server object.
System.ChassisInfo
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e and
Dell PowerEdge FX2. To obtain the chassis-specific information, use this group.
System.ChassisInfo.Model (Read Only)
Description
Indicates the LCD string the user modifies.
Legal Values String of up to 62 ASCII characters
Default Value None
Write
privilege
Not Applicable
211