The following command encrypts the specified virtual disk:
racadm storage encryptvd:Disk.Virtual.0:RAID.Integrated.1-1
NOTE: Virtual disk must be created with SED.
The following command assigns security key for controller:
racadm storage createsecuritykey:RAID.Integrated.1-1 -key <Key id> -xxx
<passphrase>
The following command modifies security key for controller:
racadm storage modifysecuritykey:RAID.Integrated.1-1 -key <Key id> -
oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
The following command deletes security key for controller:
racadm storage deletesecuritykey:RAID.Integrated.1-1
To convert the physical disk drive and assign hot-spare.
The following command converts the specified non-storage physical disk drive to a storage
capable physical disk drive:
racadm storage converttoraid:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.Integrated.1-1
The following command converts the specified physical disk drive to a non-storage physical disk
drive:
racadm storage converttononraid:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.Integrated.1-1
The following command assigns or unassigns a global or dedicated Hot spare:
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign no
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign yes -type ghs
racadm storage hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
To reset, clear, and import the storage configuration to the controller.
The following command imports the current foreign configuration from the controller:
racadm storage importconfig:RAID.Integrated.1-1
The following command clears the current foreign configuration from the controller:
racadm storage resetconfig:RAID.Integrated.1-1
The following command deletes the virtual disk from the controller:
racadm storage clearconfig:RAID.Integrated.1-1
NOTE: After a resetconfig or clearconfig operation, the data cannot be reversed.
To blink or unblink the PCIeSSD device.
The following command bilnks the specified PCIeSSD device:
racadm storage blink:Disk.Bay.8:Enclosure.Internal.0-1:PCIeExtender.Slot.3
STOR095 : Storage operation is successfully completed.
The following command unblinks the specified PCIeSSD device:
racadm storage unblink:Disk.Bay.8:Enclosure.Internal.
0-1:PCIeExtender.Slot.3
STOR095 : Storage operation is successfully completed.
To prepare the specified PCIeSSD device for removal, run the following command:
racadm storage preparetoremove: Disk.Bay.8:Enclosure.Internal.
0-1:PCIeExtender.Slot.3