Reference Guide
PatrolReadMode = Disabled
PatrolReadState = Stopped
CheckConsistencyMode = Normal
LoadBalanceSetting = Disabled
CopybackMode = OFF
PreservedCache = Not Present
CacheMemorySize = 2048 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Security Key Assigned
EncryptionMode = Supported with LKM
SasAddress = 0x5B8CA3A0F3073700
PciDeviceId = 0x5d
PciSubdeviceId = 0x1f47
PciVendorId = 0x1000
PciSubvendorId = 0x1028
PciBus = 0x3
PciDevice = 0x0
PciFunction = 0x0
BusWidth = Unknown
SlotLength = Unknown
SlotType = Unknown
MaxCapableSpeed = 12.0 Gb/s
LearnMode = Not supported
T10PICapability = Capable
SupportRAID10UnevenSpans = Supported
SupportEnhancedAutoForeignImport = Supported
EnhancedAutoImportForeignConfig = Enabled
SupportControllerBootMode = Supported
ControllerBootMode = Continue Boot On Error
RealtimeConfigurationCapability = Capable
CurrentControllerMode = RAID
The following command displays the filtered property values for all returned controller objects:
racadm storage get controllers -o -p Name
RAID.Integrated.1-1
Name = PERC H710P Adapter (Embedded)
This operation displays vdisk which has pending operation.
racadm storage get vdisks -pending
DISK.Virtual.267386880:RAID.Slot.5-1
The following command displays the output for Stash support and full controller objects along
with their keys:
racadm storage get controllers -o
RAID.Modular.3-1
Status = Ok
DeviceDescription = Integrated RAID Controller 1 in
Front Chassis Slot 3
RollupStatus = Ok
Name = Slot 3,PERC FD33xS(Controller 1)
FirmwareVersion = 25.2.2-0001
RebuildRate = 55
BgiRate = 55
CheckConsistencyRate = 55
ReconstructRate = 55
PatrolReadRate = 50
PatrolReadMode = Manual
104