Issue 8:
Description
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a
non-redundant path, the reported connected port value of the enclosures may not be accurate.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 9:
Description
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its
components (that is, EMM, PSU, fan, and temperature sensors) is reported as critical.
Resolution
If the storage enclosure is disconnected accidentally, reconnect it to get back to normal state. If it is
intentional, perform iDRAC7 reboot or server power cycle to remove the enclosure entries from the
consoles.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 10:
Description
Logging in to iDRAC7 Web interface fails with the error message 'RAC0218: The maximum number of
user sessions is reached'.
When the temporary folder used by iDRAC7 components is full, it is possible that authentication fails and
this error is displayed.
Resolution
Power cycle iDRAC7 to clear the temporary space.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 11:
Description
On Microsoft Windows7 operating system, while launching Virtual Console in native mode using
Internet Explorer, the iDRAC7 Login page is displayed.
Virtual Console uses plug-ins and due to insufficient privileges plug-in does not load and iDRAC7 Login
page is displayed.
Resolution
Reboot operating system and log in to iDRAC7 Web interface.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.