Release Notes
Issue 4:
Description
On Windows operating system, to add a folder as an image using the Virtual Media, the Desktop
directory must be in the HOMEPATH directory. The HOMEPATH directory may vary depending on the
Windows installation, but the images created from the "Add Folder as Image" operation always reside in
the
%HOMEDRIVE%\%HOMEPATH%\Desktop directory. The HOMEDRIVE must be set to C drive. Otherwise,
the operation fails.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 5:
Description
If the management station is using Linux operating system with the Pass all keystrokes to server option
enabled, you cannot resize the Virtual Console viewer window by dragging the corners or frame. This is
a limitation of X-Windows.
Resolution:
Do any of the following:
o
Disable the
Pass all keystrokes to server
option.
o
With
Pass all keystrokes to server
option enabled, open any menu in the Virtual Console viewer
window title bar, and then re-size the window.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 6:
Description
vFlash functionality remains enabled after firmware update without preserving configuration.
If vFlash functionality is enabled and a firmware update is performed without preserving the
configuration (Preserve Configuration is not selected), the vFlash Enabled option remains selected.
This is a known behavior.
Resolution
You must manually enable or disable the vFlash functionality after the firmware update as required. To
do this, select or clear the vFlash Enabled option in the iDRAC7 Web interface, or use RACADM or
WinRM remote service commands.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 7:
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the
sequence of events reported in the Lifecycle Log (or corresponding SNMP traps/email alerts) for storage
devices may not exactly match the sequence in which they occurred.
Resolution
The current state or attribute of the storage device can be checked in any of the iDRAC7 interfaces
(example, iDRAC7 Web interface, RACADM and so on).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.