Release Notes
Issue 65:
Description
On the Firmware Update page, after uploading a .img file, any subsequent request may be redirected to
the Login page. This may be due to a session timeout.
Resolution
Make sure that the session time out is set to a value that is required for the upload process to complete
(at least 2-3 minutes), depending on the file size.
Versions/Systems Affected
All 12th generation Dell PowerEdge systems with iDRAC7 1.55.55
Issue 66:
Description
Under RACADM
getsensorinfo command output, the ROMB battery reading is displayed as Unknown
and status is displayed as OK when the battery is not present.
Resolution
In the iDRAC Web interface, see the sensor page or interpret the unknown reading as battery absent.
Versions/Systems Affected
All 12th generation PowerEdge systems with iDRAC7.
Issue 67:
Description
With the certificate validation option enabled for Active Directory or Generic LDAP, replacing the
directory service CA certificate does not take effect without resetting the iDRAC.
Resolution
If the certificate validation option is enabled for Active Directory or Generic LDAP, after replacing the
directory service CA certificate, an iDRAC reset is required before attempting to log in with directory
service user or running the login test setting on the iDRAC Web interface test setting page. If it is not
possible to reset the iDRAC at this time, disable the Web server (in the Network > Services > WebServer
section, clear the Enabled option and click Apply). Wait for two minutes and then re-enable the Web
server.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 68:
Description:
Incorrect version information is provided in the Java Virtual Console About dialog box in Chinese,
Japanese and Spanish localized languages.
Resolution:
No impact.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 69:
Description
If the Rollback page is opened using Mac or Safari browser and if you click Refresh, the RAC0505 error
message is displayed.