Issue 57:
Description:
If you have configured the OS to iDRAC Pass-through channel to LOM PT mode and if the iDRAC
firmware is upgraded from 1.45.45 or lower versions to 1.50.50 or above versions, then after the firmware
upgrade, the OS to iDRAC pass-through channel setting changes to USB NIC mode (default setting).
Resolution:
After the firmware upgrade, set the OS to iDRAC Pass-through mode as LOM PT.
Versions/Systems Affected:
Platform independent.
Issue 58:
Description:
FCoEWWN and PermFCoEMACAddress are shown as all zeros in Emulex rNDCs and NICs when FCoE
partition is enabled.
Resolution:
Use one of the following work arounds to get the correct values:
•
Run
racadm get NIC.VndrConfigGroup
•
In the iDRAC Settings Utility, use the
NIC configuration
page to view the FCoE WWN.
Versions/Systems Affected
All 12
th
generation Dell PowerEdge systems with Emulex rNDCs or NICs with FCoE partition enabled with
iDRAC7 1.55.55 firmware.
Issue 59:
Description
When a MD1200/MD1220 storage enclosure’s Enclosure management module (EMM) is removed, its
temperature sensor values are shown in the iDRAC Web interface. iDRAC shows the negative readings
instead of showing them as inactive. The state of the EMM is shown as removed or failed, Only the
values are not shown intuitively to reflect its removed or failed status.
Resolution
Check the EMM’s status to make sure the temperature sensor’s readings are correct.
Versions/Systems Affected
All 12th generation PowerEdge systems with iDRAC7 and MD1200/MD1220 connected to it.
Issue 60:
Description
For servers with higher configuration (more enclosures and RAID components), firmware Racadm may
not provide the complete output for hwinventory command.
Resolution
Try using hwinventory export command.
Versions/Systems Affected
All 12th generation Dell PowerEdge systems with iDRAC7 1.50.50 or later.