Release Notes
Resolution
Update the FC16 firmware twice from the operating system (not using the iDRAC update method). For
more information, see Emulex documentation.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 43:
Description
In systems with iDRAC 1.30.30 firmware version, the
sslencryptionstrength racadm command does
not work for both firmware and local racadm interfaces.
Resolution
Use the remote racadm interface, iDRAC Web interface, or WSMAN to configure the SSL encryption
length. You can also use
idrac.webserver.LowerEncryptionBitLength object.
Versions/Systems Affected
All 12th generation Dell PowerEdge servers with iDRAC7 version 1.30.30.
Issue 44:
Description
After exiting virtual console from iDRAC sometimes invalid characters appear on the server screen when
is there is no desktop running on the server operating system.
Resolution
Launch Virtual Console and clear the Automatic System Lock option.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 45:
Description
Full export of Lifecycle Controller logs in Mac OS through Safari browser generates Log.xml file instead
of Log.xml.gz file and the Log.xml contains partial content.
Resolution
1. Open Safari in Mac.
2. Go to Safari > Preferences > General.
3. Clear the Open 'safe' files after downloading option.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 46:
Description
In some scenarios, typically when a PCIe SSD is removed from a server slot and a different PCIe SSD is
inserted within a span of 5-10 seconds into the same slot, the server fan speeds may not get optimally
configured to accommodate the thermal profile or tier of the inserted PCIe SSD.
Resolution
Power cycle the server.
Versions/Systems Affected