Release Notes
Resolution:
No impact as such, the request to delete non-existent CSC results in this message.
Versions/Systems Affected:
All Dell PowerEdge systems with iDRAC7.
Issue 34:
Description:
After uploading a custom signing certificate to iDRAC and restarting iDRAC, when you log in to iDRAC
Web interface using Firefox browser, the security certificate error is displayed. This is because the serial
number of the certificate that was stored in the Firefox browser cache is the same as the serial number
of the certificate on iDRAC.
Resolution:
Remove the browser certificate in the cache and log in to the iDRAC Web interface. For information on
removing certificates, see the Firefox documentation. If the problem persists:
1. Log in to iDRAC using racadm and run sslresetcfg.
2. Perform steps to upload custom signing certificate.
Issue 35:
Description
On PowerEdge M520, if a Broadcom 57810S DP 10G KR Mezz 55 GHP or Qlogic DP 10 Gb SFP+/DA CNA
Mezz RX8GJ is installed, an additional blank entry is displayed in the System Inventory page of the Web
interface and on other interfaces such as RACADM, WSMAN, and Lifecycle Controller GUI.
Resolution
This is a false entry and can be ignored.
Versions/Systems Affected
Dell PowerEdge M520
Issue 36:
Description
Sometimes invalid characters are displayed on the server console screen after exiting iDRAC Virtual
Console.
Resolution
Launch virtual console and clear the Automatic System Lock option.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 37:
After an iDRAC7 firmware update, some of the iDRAC7 Web interface panels or navigation menu items
may contain incorrect or invalid entries.
Resolution
Clear your browser cache(s) after updating the iDRAC7 firmware.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.