Release Notes
Alternately, restoring the previous Java version also prevents the display of the message. See the Oracle
Java documentation for information on how to uninstall Java.
After uninstalling, re-install Java 7 update 21 (or your preferred version).
Versions/Systems Affected
All versions of iDRAC on 12th generation Dell PowerEdge Servers.
Issue 57:
Description
If the default https port 443 is changed using any interface, you cannot access the Web interface, but can
access RACADM and WS-MAN interfaces. iDRAC Web interface is not redirecting to Login page after
changing the port value for https redirection.
Resolution
To access the Web interface, change the https port number to 443 using RACADM or WS-MAN.
Versions/Systems Affected
All 12th generation Dell PowerEdge Systems with iDRAC7 1.50.50 or later.
Issue 58:
Description
For blade servers with Microsoft Windows operating system in Chinese (ZH) or Japanese (JA) locale,
starting the Virtual Console using Java plug-in is unsuccessful when using the Chrome browser.
Resolution
Use the Firefox browser and retry the operation.
Versions/Systems Affected
All 12th generation Dell PowerEdge servers with iDRAC7 1.50.50 or later.
Issue 59:
Description
iDRAC Link local IPv6 address changes from bond0 local link address to USB0 local link address as soon
as the OS to iDRAC pass-through is enabled in USB mode.
Resolution
Save bond0 interface’s link local IPv6 address before enabling the USB mode for later usage.
Versions/Systems Affected
Platform independent.
Issue 60:
Description
In the case where an NDC supports OS to iDRAC Pass-through feature, but software arbitration is
enabled for NC-SI, the LOM option must be hidden in the iDRAC configuration for OS to iDRAC Pass-
through.
Resolution
Use OS to iDRAC Pass-through channel in USB NIC mode.
Versions/Systems Affected:
Full Height PowerEdge M820 server with Emulex bNDC ((which supports OS to iDRAC Pass-through but
does not support hardware arbitration).