Reference Guide
– chassis
This option is applicable for CMC only.
• -l <ledstate> — Specifies whether the LED must blink.
<ledstate> can be one of the following:
– 0: no blinking
– 1: blinking
Example For CMC:
• racadm setled -m server-1 -1 1
LED state was set successfully.
• racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the server in slot 1.
NOTE: The setled command generates an error when run on the extension slot of a
multi-slot server.
For iDRAC:
racadm setled -l 1
LED state was set successfully.
setniccfg
Description Sets the iDRAC IP address. It displays an error message if the requested operation could not be
performed. A success message is displayed if the operation is completed successfully
To run this subcommand, you must have the Configure iDRAC permission.
.
NOTE: For CMC, the command helps to modify network configuration properties.
NOTE: The terms NIC and Ethernet management port may be used interchangeably.
Synopsis
• racadm setniccfg -d
• racadm setniccfg -d6
• racadm setniccfg -s <IPv4Address> <netmask> <IPv4 gateway>
• racadm setniccfg -s6 <IPv6 Address> <IPv6 Prefix Length> <IPv6
Gateway>
• racadm setniccfg -o
For CMC:
• racadm setniccfg -m <module> -v <vlan ID> <vlan priority>
• racadm setniccfg [-m chassis] -o
• racadm setniccfg –p [-6]
• racadm setniccfg -m <module> -k <speed> <duplex>
• racadm setniccfg -i <slot> -v <vlan ID> <vlan priority>
123