Reference Guide
• -assign {yes | no} — Assigns or unassigns the disk as a hot-spare.
• -type { ghs | dhs} — Assigns a global or dedicated hot-spare.
• -vdkey:<VD FQDD> — Assigns the dedicated hot-spare to the specified virtual disk. This
option is required for dedicated hot-spare.
Example
• To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical
disk drives.
– To generate and view information about the inventory of storage root node.
This command retrieves the status.
racadm raid get status
Storage Root Node Status : Ok
– To generate and view information about the inventory of controllers connected to the server.
racadm raid get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o
RAID.Integrated.1-1Status = Ok
DeviceDescription = Integrated RAID Controller 1
RollupStatus = Ok
Name = PERC H710P Adapter (Embedded)
FirmwareVersion = 21.2.0-0007
DriverVersion = 6.600.18.00
RebuildRate = 30 %
BgiRate = 30 %
CheckConsistencyRate = 30 %
ReconstructRate = 30 %
PatrolReadRate = 30 %
PatrolReadMode = Automatic
PatrolReadState = Unknown
CheckConsistencyMode = Normal
LoadBalanceSetting = Auto
CopybackMode = ON
PreservedCache = Not Present
CacheMemorySize = 1024 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Encryption Capable
EncryptionMode = None
SasAddress = 0x5B8CA3A0EB118A00
PciDeviceId = 0x5b
PciSubdeviceId = 0x1f31
PciVendorId = 0x1000
PciSubvendorId = 0x1028
PciBus = 0x4
PciDevice = 0x0
PciFunction = 0x0
BusWidth = Unknown
SlotLength = Information Not Available
SlotType = Unknown
MaxCapableSpeed = 6.0 Gb/s
LearnMode = Not supported
T10PICapability = Not Capable
SupportRAID10UnevenSpans = Not Supported