Reference Guide

-assign {yes | no} — Assigns or unassigns the disk as a hot-spare.
-type { ghs | dhs} — Assigns a global or dedicated hot-spare.
-vdkey:<VD FQDD> — Assigns the dedicated hot-spare to the specified virtual disk. This
option is required for dedicated hot-spare.
Example
To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical
disk drives.
To generate and view information about the inventory of storage root node.
This command retrieves the status.
racadm raid get status
Storage Root Node Status : Ok
To generate and view information about the inventory of controllers connected to the server.
racadm raid get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o
RAID.Integrated.1-1Status = Ok
DeviceDescription = Integrated RAID Controller 1
RollupStatus = Ok
Name = PERC H710P Adapter (Embedded)
FirmwareVersion = 21.2.0-0007
DriverVersion = 6.600.18.00
RebuildRate = 30 %
BgiRate = 30 %
CheckConsistencyRate = 30 %
ReconstructRate = 30 %
PatrolReadRate = 30 %
PatrolReadMode = Automatic
PatrolReadState = Unknown
CheckConsistencyMode = Normal
LoadBalanceSetting = Auto
CopybackMode = ON
PreservedCache = Not Present
CacheMemorySize = 1024 MB
PersistHotspare = Disabled
SpindownUnconfiguredDrives = Disabled
SpindownHotspare = Disabled
Timeintervalforspindown = 30 (Minutes)
SecurityStatus = Encryption Capable
EncryptionMode = None
SasAddress = 0x5B8CA3A0EB118A00
PciDeviceId = 0x5b
PciSubdeviceId = 0x1f31
PciVendorId = 0x1000
PciSubvendorId = 0x1028
PciBus = 0x4
PciDevice = 0x0
PciFunction = 0x0
BusWidth = Unknown
SlotLength = Information Not Available
SlotType = Unknown
MaxCapableSpeed = 6.0 Gb/s
LearnMode = Not supported
T10PICapability = Not Capable
SupportRAID10UnevenSpans = Not Supported
110