Release Notes
Resolution:
Do any of the following:
•
Disable the
Pass all keystrokes to server
option.
•
With
Pass all keystrokes to server
option enabled, open any menu in the Virtual Console viewer
window title bar, then re-size the window.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 6:
Description
vFlash functionality remains enabled after firmware update without preserving configuration.
If vFlash functionality is enabled and a firmware update is performed without preserving the
configuration (Preserve Configuration is not selected), the vFlash Enabled option remains selected.
This is a known behavior.
Resolution
You must manually enable or disable the vFlash functionality after the firmware update as required. To
do this, select or clear the vFlash Enabled option in the iDRAC7 Web interface, or use RACADM or
WinRM remote service commands.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge(TM) systems.
Issue 7:
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the
sequence of events reported in the Lifecycle Log (or corresponding SNMP traps/email alerts) for storage
devices may not exactly match the sequence in which they occurred.
Resolution
The current state or attribute of the storage device can be checked in any of the iDRAC7 interfaces
(example, iDRAC7 Web interface, RACADM and so on).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 8:
Description
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a
non-redundant path, the reported connected port value of the enclosures may not be accurate.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 9:
Description
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its
components (that is, EMM, PSU, fan, and temperature sensors) is reported as critical.