Release Notes
Issue 28
Description
When video player is launched it launches both playback control window and playback window. On Linux RHEL6.0 work
station, if playback window lost focus then user cannot switch back by using mouse. It is not an issue on Microsoft Windows
workstations.
Resolution
This is an issue with the RHEL 6.0 version of Linux. Close the playback control window by selecting 'x' and select playback
program on task bar using mouse to bring up playback window. If you need to bring up playback controls again then select
menu item from playback window.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
LC2-RS – Notes
Auto Discovery messages are now recorded in the Lifecycle Log.
Driver Pack updates no longer require a reboot.
The ‘
Automated Task Engine
’ screen now displays scheduled jobs with a ‘Running’ status unlike previous versions.
Empty partitions are created quickly when other partitions are not in use. If other partitions are in use, then
creating an empty partition takes longer. For example, attach partition, format partition, and so on.
Lifecycle Controller job scheduling is enhanced. Jobs scheduled in the same group are executed in a sequence.
Jobs that are not in the same group and scheduled at the same time execute at the scheduled time in parallel.
Passwords included in URI strings must use the correct percent-encoding format.
The string value for Challenge-Handshake Authentication Protocol (CHAP) passwords must have either zero or
between 12 to 16 characters.
Changing the system password and locking the password cannot be done in a single Lifecycle Controller job. Run a
job to change the password, reboot the host, and then run another job to lock the password.
System Characterization must be enabled to correctly run the firmware update during system power on after a
Power Supply Unit (PSU) replacement. If System Characterization is not enabled, the firmware update runs after
the next host reboot.
If the system is shut down or left in the shutdown state while a job is in progress, the job cannot progress further.
Delete the job and run it again.