Release Notes

Intel(R) Ethernet 10G X520 LOM
Intel(R) Ethernet 10G 2P X550-t Adapter
While installing the operating system on 12th generation PowerEdge servers by using LC UI, ensure that the virtual media is attached
on the server before BIOS boot.
On NANO operating system, you cannot install a firmware or driver DUP if it is in .exe format.
During the RAID Configuration, on the Step 3 of 5: Select Physical Disk page, the scroll bar of Select Physical Pool table is not
displayed. To view the scroll bar:
Hover your mouse over the right edge of the table.
Press Tab until the table is selected.
This issue is observed when you select the RAID level as 0, 5, 6, 10, 50, or 60.
When using Internet Explorer or Google Chrome to access the HTML5 virtual console from a Windows OS, the floating menu at the
top of the window may not be displayed.
Known Issues—To be fixed in future releases
1. Description
Some of the supported components are not displayed on the Firmware Update > View Current Versions page.
Workaround
Restart the system and open View Current Versions page.
Systems affected: All systems supported by this release.
Tracking number: N/A
2. Description
If a Mellanox card is present in the system, then under Network Settings, the port number must be displayed as Port 1 and Port 2
because it is a dual port. But, the port number is displayed as Port 1 for both the ports or the port numbers are not displayed.
Workaround
To distinguish between the port numbers, see the MAC address or the Device Settings. You can access Device Settings in the
following methods:
During Post, press F2, and select System Setup.
On the Lifecycle Controller Home page, click System Setup, and then click Advanced Hardware Configuration.
Systems affected: All systems supported by this release.
Tracking number: N/A
3. Description
After you successfully update the firmware of a CPLD on a modular server, and then perform a firmware update operation of a
component that requires a system restart (such as BIOS), the server is automatically and repeatedly restarted.
Workaround
Perform a Power Cycle operation on the server.
Systems affected: All systems supported by this release.
Tracking number: N/A
4. Description
On 12
th
generation of PowerEdge servers, while deploying the operating system by selecting the UEFI boot mode, an error message is
displayed when you click Finish. This error occurs if you try to connect the optical drive or virtual media after you launch Lifecycle
Controller.
Workaround
Reboot the server and ensure that you connect the optical drive or virtual media before launching Lifecycle Controller.
Systems affected: All systems supported by this release.
Tracking number: N/A
5. Description
6
Known Issues—To be fixed in future releases