Release Notes
• Try launching the virtual console again.
• From CMC, access the iDRAC web interface and then launch the virtual console from the iDRAC web interface.
Systems aected: All systems supported by this release.
Tracking number: 105420
11 Description
If the system has both Emulex OCm14102 and Emulex LPm16002, and if you want to update the rmware from version 02.00.04 or
earlier to a newer version, update the rmware for Emulex LPm16002 rst. After the rmware update for Emulex LPm16002 is
complete, you can update the rmware for Emulex OCm141102.
Workaround N/A
Systems aected: All systems supported by this release.
Tracking number: 106560
12 Description
The description for P4510 and P4610 Intel PCIe SSD drives is displayed as ‘Express Flash NVMe P4500/P4600’ instead of ‘Express
Flash NVMe P4510/P4610’.
Workaround N/A
Systems aected: All systems supported by this release.
Tracking number: 114392
13 Description
iDRAC rmware update from the OS may fail with an error about virtual device being unreachable because of BitLocker or other
security software.
Workaround Retry the update.
Systems aected: PowerEdge R820 and R30xd
Tracking number: 114604
14 Description
On a system with cabled PSU, if you press the system identication button repeatedly, it may cause iDRAC to stop responding for
some time.
Workaround N/A
Systems aected: All systems supported by this release.
Tracking number: 116571
16