CLI Guide
• -f <filename> — Enables set to congure the device from a specied le. This option is not supported in
the Firmware RACADM interface.
• --continue — This option is used with –f only and is applicable for only for INI le operation.. If a multi-object
Set is unsuccessful for a <group>, then Set continues with the next <group> in the le. If this option is not
used, then Set stops when it is unsuccessful for a particular <group>. After the unsuccessful <group>, the
remaining <group>s are not congured.
NOTE:
This option is applicable only for INI le operation.
• -u — Species user name of the CIFS remote share from which the le must be imported
• -p — Species password for the remote CIFS share from which the le must be imported.
• -l — Species network share location from where the le must be imported.
• -t — Species the le type to be imported. Valid values are xml and INI.INI les can only be imported from a
local le. XMLimports the Server Conguration Prole in XMLformat either from a local or network share le.
NOTE: To import or export Server Conguration Prole.xml, use the Lifecycle Controller version 1.1 or
later.
Staging and reboot control options
The following options control when and how system reboots are performed when using the –f option. As noted
above, some FQDDs require a system reboot to apply the new values; other FQDDs optionally support immediate
application of new values. If the imported le contains ONLY immediate application-capable FQDDs such as iDRAC,
do NOT use the –b option and the Set command will schedule a real-time job to immediately apply the new values.
NOTE: The –b, -w, –s, and --preview options are applicable only with –f option.
• -b — . Species the type of shutdown for the system after a le import operation completes. The parameters
are
Graceful, Forced, and NoReboot for graceful shutdown, forced shutdown, and no reboot respectively. If
-b is not specied, graceful shutdown is taken as the default except as noted above for les containing new
values for immediate application-capable <FQDD>s.
NOTE
: If the operating system is in use, then the graceful shutdown option may time out within
300 seconds. If this operation is unsuccessful, then retry with the force option.
• -w — Maximum time to wait for the graceful shutdown to occur. The value must be entered in seconds.
Minimum accepted value is 300 seconds and the maximum accepted value is 3600 seconds. The default value is
1800 seconds.
• -s — Power state of the host when the import operation completes. The parameters are "On" for powered ON
and "O" for powered OFF. If this parameter is not specied, power ON is taken as default.
• --preview — Validates the conguration .xml le and view the status.
The --preview option provides the Job ID to verify the status of the le preview operation. The Job ID can be
tracked by running the racadm jobqueue view –I <JID> command.
NOTE
:
– The --preview option does not restart the system.
– The-b,-w options cannot be included with the --preview option.
– A scheduled job or pending conguration should not be running while using the --preview option.
• -c — Species the FQDD or list of FQDDs separated by ',' of the components for which the congurations
should be imported. If this option is not specied, conguration related to all the components are imported.
NOTE
: To use the -c or --preview option, the minimum Lifecycle Controller version required is 1.2.
NOTE: On certain devices, importing the server conguration prole requires two imports to apply the
conguration to all the devices. The rst import of the prole enables hidden devices which are then
congured with a second import. The devices that require two imports are as follows:
• PERC S110 and PERC S130 controllers
• PCI slots in the system that are disabled in the BIOS
RACADM Subcommand Details 99