CLI Guide
– SEL
– RACLOG
– DE
– WSMAN
– RACADM
– iDRAC_GUI
• -k—Filters the records based on the lter string provided in racadm lclog view command.
• -c—The category used to lter the records. Provides multiple categories using a "," as the delimiter. The value is
case-insensitive. Valid category values:
– System
– Storage
– Worknotes
– Config
– Updates
– Audit
• -b —The subcategory used to lter the records. Provides multiple subcategories using a "," as the delimiter.
• -q—The sequence number from which the records must be displayed. Records older than this sequence
number is displayed.
NOTE: This parameter input is an integer. If an alphanumeric input is provided, then invalid
subcommand syntax error is displayed.
• -n—Species the n number of records that must be displayed. On Local RACADM, if this parameter is not
specied, by default 100 logs are retrieved.
• -r—Displays events that have occurred after this time. The time format is yyyy-mm-dd HH:MM:SS. The time
stamp must be provided within double quotation marks.
• -e—Displays events that have occurred before this time. The time format is yyyy-mm-dd HH:MM:SS. The time
stamp must be provided within double quotation marks.
• -f <filename>—Species the le location and name where lifecycle log is exported.
• -a <name>—Species the FTP Server IP address or FQDN, user name, and password.
• -l <location>—Species the location of the network share or area on le system where lifecycle log is
exported. Two types of network shares are supported:
– SMB-mounted path: //<ipaddress or domain name>/<share_name>/<path to image>
– NFS-mounted path: <ipaddress>:/<path to image>.
• -u <user>—Species the user name for accessing the FTP server, or Domain and user name for accessing
network share location.
• -p <password>—Species the password for accessing the FTP server or share location.
• -s—The severity used to lter the records. Provide multiple severities using a "," as the delimiter. The value is
case-insensitive. Valid Severity values:
– Warning
– Critical
– Info
• —m <Comment> —User comment string for a record that must be inserted in the Lifecycle Controller log. This
comment string must be less than 128 characters. The text must be specied within double quotation mark.
NOTE
: HTML-specic characters may appear as escaped text.
• -m <Worknote>—Adds a worknote (an entry) in the Lifecycle log. This worknote must be less than 256
characters. The text must be specied within double quotation mark.
NOTE
: HTML-specic characters may appear as escaped text.
NOTE: For -m <worknote> and —m <comment> options, you need test alert privilege.
• --complete—Export the complete Lifecycle log as a compressed le. The exported le will be of the
type
.xml.gz.
RACADM Subcommand Details
83