CLI Guide

Storage.Controller
The objects in this group manage storage controller attributes. This group is indexed.
The following sections provide information about the objects in this group.
Storage.Controller.BackgroundInitializationRate (Read or
Write)
Table 1225. Details of Storage.Controller.BackgroundInitializationRate attribute
Description The Background Initialization (BGI) rate is the percentage of the system's resources dedicated to perform the
background initialization of a virtual disk after it is created.
Legal Values Values: 0–100
Default value 100
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.BatteryLearnMode (Read Only)
Table 1226. Details of Storage.Controller.BatteryLearnMode attribute
Description Battery Learn Mode controls a RAID controller's Battery Learn Cycle.
Legal Values
Automatic
Warn
Disabled
Not Supported
Default value None
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency A battery must be present on the controller.
Storage.Controller.CheckConsistencyMode (Read or Write)
Table 1227. Details of Storage.Controller.CheckConsistencyMode attribute
Description Check Consistency feature is used to verify the accuracy of the redundant (parity) information.
Legal Values
Normal
Stop On Error
544 Database Objects With Get and Set Commands