CLI Guide
System.ThermalCong.CriticalEventGenerationInterval (Read
or Write)
Table 481. Details of System.ThermalCong.CriticalEventGenerationInterval
Description Indicates the time interval (in days) for critical events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.EventGenerationInterval (Read or
Write)
Table 482. Details of System.ThermalCong.EventGenerationInterval
Description Indicates the time interval (in days) for warning events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.FreshAirCompliantConguration (Read
Only)
Table 483. Details of
System.ThermalCong.FreshAirCompliantConguration
Description Indicates whether or not the system is congured to be fresh air compliant.
Legal Values
• 0 — Not Applicable
• 1 — Yes
• 2 — No
Default Value 1 — Yes
License Required iDRAC Express or iDRAC Enterprise
Dependency None
268 Database Objects With Get and Set Commands