CLI Guide
Use this object with the cong or getcong subcommands.
The following sections provide information about the objects in the cfgSerial group.
NOTE: The cfgSerial object group is applicable for iDRAC Enterprise on Blade Servers for only two properties —
cfgSerialTelnetEnable=1 and cfgSerialSshEnable=1.
cfgSerialBaudRate - Read or Write
Table 156. Details of cfgSerialBaudRate attribute
Description
Sets the baud rate on the serial port.
Legal Values
9600, 19200, 57600, 115200
Default
57600
cfgSerialConsoleEnable - Read or Write
Table 157. Details of cfgSerialConsoleEnable attribute
Description
Enables or disables the serial console interface.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
0
cfgSerialConsoleQuitKey (Read or Write)
Table 158. Details of cfgSerialConsoleQuitKey attribute
Description
This key or key combination terminates Virtual Console text for iDRAC when using the console com2 command.
Legal value: ^ follows any alphabet (a-z, A-Z) ^ follows the listed special characters: [ ] \ ^ _
NOTE: The CTRL key is represented by using the ^ (carat) character.
NOTE: The CTRL key does not generate a character by itself, but must be struck simultaneously with
another key to generate a character.
For example, striking both the CTRL key and the \ key simultaneously (rather than sequentially) is denoted as ^\.
Conguration options: The value must start with the ^ character, and must follow one of the characters — a-z, A-Z,
[,], \
In the input command, use \ without the quotes. For example:
config -g cfgSerial -o cfgSerialConsoleQuitKey "SHIFT+6"\\
iDRAC Property Database Group and Object Descriptions 157