CLI Guide
SupportEnhancedAutoForeignImport = Supported
EnhancedAutoImportForeignConfig = Enabled
SupportControllerBootMode = Supported
ControllerBootMode = Continue Boot On Error
RealtimeConfigurationCapability = Capable
CurrentControllerMode = RAID
BootVD = Disk.Virtual.0:RAID.Integrated.1-1
The following command displays the ltered property values for all returned controller objects:
racadm storage get controllers -o -p Name
RAID.Integrated.1-1
Name = PERC H710P Adapter (Embedded)
The following examples show the pending operation when used with storage get <object> commands:
To list storage objects without displaying the properties:
◦ This operation displays vdisk, which has pending operation:
racadm storage get vdisks -pending
DISK.Virtual.267386880:RAID.Slot.5-1
◦ This operation displays controllers, which have pending operations:
racadm storage get controllers -pending
RAID.Integrated.1-1
◦ This operation displays pdisk, which has pending operation:
racadm storage get pdisks -pending
Disk.Bay.20:Enclosure.Internal.0-1:RAID.Integrated.1-1
◦ This operation displays enclosures, which have pending operations:
racadm storage get enclosures -pending
Enclosure.Internal.0-1:RAID.Integrated.1-1
Changing the attribute by using racadm set storage or storage conguration command displays the storage object in the -
pending command output. If there are no pending objects, the following error message is displayed:
racadm storage get pdisks -pending
ERROR: STOR0103 : No physical disks are displayed.
Check if the server has power, physical disks are available, and physical disks are
connected to the enclosure or backplane.
The following examples show the pending operation while listing the properties:
By default, if there is no change in properties, the -pending command displays the current value. If the property has any pending
objects, the -pending command displays the pending value.
◦ This operation displays the current state of pdisk, which is in Ready state:
/admin1-> racadm storage get pdisks -o -p state
Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
State = Ready
◦ This operation displays state of a pdisk on which createvd operation is pending:
/admin1-> racadm storage get pdisks -o -p state -pending
Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1
The following command displays the output for PowerEdge FD332 support and full controller objects along with their keys:
racadm storage get controllers -o
RAID.Modular.3-1
Status = Ok
DeviceDescription = Integrated RAID Controller 1 in Front Chassis Slot 3
RollupStatus = Ok
Name = Slot 3,PERC FD33xS(Controller 1)
FirmwareVersion = 25.2.2-0001
RebuildRate = 55
BgiRate = 55
CheckConsistencyRate = 55
ReconstructRate = 55
RACADM Subcommand Details