CLI Guide
wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|
16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|
16M}]-pdkey:<comma separated PD FQDD> [-dcp
{enabled|disabled|default}] [-name <VD
name>] [-size <VD size>{b|k|m|g|t}] [-
T10PIEnable]
NOTE: T10PI is not supported on PERC 9 and PERC
10.
racadm storage init:<VD FQDD> -speed {fast|
full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage
createsecuritykey:<Controller FQDD> -key
<Key id> -xxx <passphrase>
NOTE: createsecuritykey command is not supported on
H3xx PERC controllers.
racadm storage
modifysecuritykey:<Controller FQDD> -key
<Key id>-xxx <old passphrase> -xxx <new
passphrase>
racadm storage
deletesecuritykey:<Controller FQDD>
racadm storage ccheck:<vdisk fqdd>
racadm storage cancelcheck:<vdisk fqdd>
• To convert the physical disk drives and assign or delete a
hotspare. To scan physical disks connected to a controller and
detect problem, run the following command:
racadm storage converttononraid:<PD FQDD>
NOTE
: Convert to RAID and non-RAID is not supported
on PERC 10 and BOSS controllers.
racadm storage converttoraid:<PD FQDD>
racadm storage hotspare:<Physical Disk
FQDD> -assign yes -type dhs -vdkey: <FQDD
of VD>
racadm storage hotspare:<Physical Disk
FQDD> -assign yes –type ghs
racadm storage hotspare:<Physical Disk
FQDD> -assign no
racadm storage patrolread:<controller FQDD>
-state start|stop
racadm raid cancelbgi:<VD FQDD>
racadm raid replacephysicaldisk:<PD FQDD> -
dstpd <PD FQDD>
110
RACADM Subcommand Details