Release Notes

Dell tracking: 83908
15 Description
If the retry count is set to 0, SNMP Get requests may time out.
Resolution
To avoid the timeout, use a retry count of at least 1.
Version/Systems aected: All systems with iDRAC7 and iDRAC8.
Dell tracking: 92702
16 Description
iDRAC rmware update using RACADM fails and incorrect version information is displayed with OpenManage 9.
Resolution
Update the rmware using other methods such as iDRAC web interface, using DUPs through the operating system, and so on.
Version/Systems aected: All systems with iDRAC7 and iDRAC8.
Dell tracking: 83577, 84851
17 Description
On a system with cabled PSU, if you press the system identication button repeatedly, it may cause iDRAC to stop responding for
some time.
Workaround N/A
Systems aected: All systems supported by this release.
Tracking number: 116571
Known Issues — To be
xed in future releases 17