Release Notes
Table Of Contents
- iDRAC8/7 with Lifecycle Controller Version 2.52.52.52 Release Notes
- Overview
- Platforms affected
- What is supported
- New in this release
- Fixes
- Important notes
- Limitations
- Known Issues — To be fixed in future releases
- Installation
- Lifecycle Controller Remote Services — client tools
- Accessing documents from Dell Support site
- Contacting Dell EMC
Version/Systems aected:PowerEdge systems with iDRAC7.
Dell tracking: 69935
10 Description
After scheduling an recurring automatic update, if user disables Lifecycle Controller the subsequent scheduled job will be deleted and
will log a message as Jobs deleted as Automatic Update Feature disabled, even though the automatic update feature is enabled and
only Lifecycle Controller is disabled.
Resolution
To continue to allow scheduled updates, verify if automatic update feature is enabled and Lifecycle Controller is enabled.
Version/Systems aected: All PowerEdge systems with iDRAC7 and iDRAC8.
Dell tracking: 70567
11 Description
Upon execution of the RACADM command racadm eventfilters get –c idrac.alert.all using local RACADM, the
event lter information is not obtained.
Resolution
Use Remote RACADM, CMC rmware RACADM, or CMC GUI.
Version/Systems aected: All systems with iDRAC7 and iDRAC8.
Dell tracking: 29203
12 Description
Export and import operations from iDRAC web interface and RACADM fail when a CIFS share congured with NTLM V2 is used.
Resolution
Use WSMan or Redsh interfaces for import and export operations to CIFS shares congured with NTLMv2 when the security option
selected is Send NTLMv2 response only. Refuse LM & NTLM.
Version/Systems aected: All PowerEdge systems with iDRAC7 and iDRAC8.
Dell tracking: 72257
13 Description
If the iDRAC HTML5 vConsole viewer is launched repeatedly, without any delay between the launches, an error message about
dropped network connection may be displayed.
Resolution
Re-launch the viewer from the iDRAC web GUI after a few seconds.
Version/Systems aected: All PowerEdge systems with iDRAC versions 2.40.xx.xx and 2.50.xx.xx.
Dell tracking: 71591
14 Description
A hardware inventory export command executed from Remote RACADM to a local share fails. This failure happen only with
OpenManage 9.1.
Resolution
You can use one of the following methods:
• Use an earlier version of OpenManage, such as OpenManage 8.5.
• Export the hardware inventory using rmware RACADM to NFS/CIFS share.
• Use local RACADM.
Version/Systems aected: All systems with iDRAC7 and iDRAC8 with OpenManage 9.1
16