Release Notes
10 Description
Upon execution of a RACADM proxy command using local RACADM, the command to create a username in CMC does not allow a
successful execution when the username string provided has an empty space character embedded within.
Resolution
Use Remote RACADM, CMC rmware RACADM, or CMC GUI.
Version/Systems aected:CMC
Dell tracking: 26772
11 Description
Upon execution of the RACADM command racadm eventfilters get –c idrac.alert.all using local RACADM, the
event lter information is not obtained.
Resolution
Use Remote RACADM, CMC rmware RACADM, or CMC GUI.
Version/Systems aected: All systems with iDRAC7 and iDRAC8.
Dell tracking: 29203
12 Description
Unable to view HW and SW Inventory through local RACADM interface, when all the possible VD’s are created and mapped to all
possible volumes (allowed 24) to HOST windows OS.
Resolution
Use Remote RACADM, CMC rmware RACADM, or other iDRAC interfaces (GUI/WSMan).
Version/Systems aected: All PowerEdge systems with iDRAC7 and iDRAC8.
Dell tracking: 24244
13 Description
Export and import operations from iDRAC web interface and RACADM fail when a CIFS share congured with NTLM V2 is used.
Resolution
Use WSMan or Redsh interfaces for import and export operations to CIFS shares congured with NTLMv2 when the security option
selected is Send NTLMv2 response only. Refuse LM & NTLM.
Version/Systems aected: All PowerEdge systems with iDRAC7 and iDRAC8.
Dell tracking: 72257
14 Description
If the iDRAC HTML5 vConsole viewer is launched repeatedly, without any delay between the launches, an error message about
dropped network connection may be displayed.
Resolution
Re-launch the viewer from the iDRAC web GUI after a few seconds.
Version/Systems aected: All PowerEdge systems with iDRAC versions 2.40.xx.xx and 2.50.xx.xx.
Dell tracking: 71591
15 Description
By default, LC GUI and iDRAC interfaces use SMB1 protocol. If SMB1 is disabled on Windows or Samba CIFS shares, all features that
use this share fail.
Resolution
18