Release Notes
Important notes
1 The supported version of VMCLI is available in OpenManage 9.0.2 release. Go to dell.com/openmanagemanuals and click Open
Manage Software > Dell OpenManage Software Version 9.0.2 > Drivers & downloads.
2 If you execute multiple jobs for various components and iDRAC DUP is one of the jobs, ensure that iDRAC job is the last job in the
queue. Ensure that all other jobs are either in SCHEDULED or COMPLETED state before you execute the iDRAC job.
3 Windows Server 2012, Windows Server 2008 R2, and Windows 7 do not support TLS 1.2 and TLS 1.1. Install the following update to
enable TLS 1.2 and TLS 1.1 as a default secure protocols in WinHTTP in Windows:
http://support.microsoft.com/kb/3140245/EN-US
4 Supports LDAP authentication with OPEN-DS. OPEN-DS must have DH key larger than 768 bits.
5 The drivers exposed by LC are present in a read-only drive labeled OEMDRV and the drive is active for 18 hours. During this period:
• You cannot install any DUPs.
• LC cannot invoke CSIOR.
However, if an AC power cycle (cold boot) is performed, the OEMDRV drive is automatically deleted.
6 CPLD rmware update has no impact on Trusted Platform Module enablement.
7 Depending on the virtual storage device attached through iDRAC, that is, USB drive or CD/DVD .ISO le, LC displays Virtual Floppy
or Virtual CD respectively.
8 If Test Network Connection fails for a valid address, try conguring the network settings again. If the issue persists, restart the system
and retry the operation.
9 When you reset or update the iDRAC, you must reboot LC if it is launched already. If you fail to reboot, LC may behavior unexpectedly.
10 On PowerEdge FC630, PowerEdge FC830, and PowerEdge FC430 systems, part replacement is not supported if a single PERC
(FS332) is replaced with a dual PERC (FD332) or vice-versa.
11 After performing a rmware update or rollback operations from LC, the host is rebooted by default. Reboot the host server again to
display the updated rmware versions in the Hardware Conguration wizard.
12 To record updates in the Lifecycle Log, ensure that the Lifecycle Controller and iDRAC are from the same release.
13 If Lifecycle Controller and iDRAC are not from the same release, the Lifecycle Log displays either blank messages or messages with a
“~” character.
14 When you update a 12th generation PowerEdge server backplane-expander rmware for PowerEdge R920 rmware to version 0.33
or 2.03, the comparison page displays only one expander entry. However, rmware for both the expanders is updated.
15 Fibre channel NIC cards with two or four ports are displayed as a single port card in Lifecycle Controller. However, all ports are
updated when a rmware update is performed.
16 The option to enable or disable the disk cache policy for SWRAID controllers is supported only on SWRAID controller driver version
4.1.0-0025 or later.
17 ResetKeys under Action in the SecureBoot resource is available only on systems with supported BIOS.
18 The SecureBoot navigation link is available under Computer System only if the SecureBoot feature is supported by the BIOS installed
on the system.
19 Rollback is not supported for CPLD.
20 The time taken to complete a Patch operation using Redsh depends on the number of attributes that you are trying to modify.
6