Reference Guide
Conguration
• To view the help details for a conguration command, run the following command:
racadm storage help <command>
where command can take below values
converttoraid, converttononraid, controllers, clearconfig, createsecuritykey,
createvd, deletesecuritykey, deletevd, encryptvd, enclosures, emms, fans,
hotspare, importconfig, ccheck, secureerase, preparetoremove, blink, unblink,
cancelcheck, init, modifysecuritykey, psus, pdisks, resetconfig, tempprobes,
vdisks, and patrolread.
• To create, delete, and secure the virtual disks. To start or stop the consistency check on the specied virtual disk,
run the following command:
racadm storage createvd:<Controller FQDD> -rl {r0|r1|r5|r6|r10|r50|r60}[-wp
{wt|wb|wbf}] [-rp {nra|ra|ara}] [-ss {1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|
1M|2M|4M|8M|16M}]-pdkey:<comma separated PD FQDD> [-dcp {enabled|disabled|
default}] [-name <VD name>] [-size <VD size>{b|k|m|g|t}] [-T10PIEnable]
racadm storage init:<VD FQDD> -speed {fast|full}
racadm storage deletevd:<VD FQDD>
racadm storage encryptvd:<VD FQDD>
racadm storage createsecuritykey:<Controller FQDD> -key <Key id> -xxx
<passphrase>
racadm storage modifysecuritykey:<Controller FQDD> -key <Key id>-xxx <old
passphrase> -xxx <new passphrase>
racadm storage deletesecuritykey:<Controller FQDD>
racadm storage ccheck:<vdisk fqdd>
racadm storage cancelcheck:<vdisk fqdd>
• To convert the physical disk drives and assign or delete a hotspare. To scan physical disks connected to a
controller and detect problem, run the following command:
racadm storage converttononraid:<PD FQDD>
racadm storage converttoraid:<PD FQDD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes -type dhs -vdkey:
<FQDD of VD>
racadm storage hotspare:<Physical Disk FQDD> -assign yes –type ghs
racadm storage hotspare:<Physical Disk FQDD> -assign no
racadm storage patrolread:<controller FQDD> -state start|stop
NOTE
: If the –assign option is no, you cannot add other options. If the –assign option is yes
and if the -type option is not present, the global hotspare (ghs) is created by default.
• To reset, clear, and import the storage conguration to the controller, run the following command:
racadm storage importconfig:<Controller FQDD>
racadm storage resetconfig:<Controller FQDD>
racadm storage clearconfig:<Controller FQDD>
• To start or stop a blink or identify operation on the specied or PCIeSSD device, run the following command:
racadm storage blink:<FQDD>
racadm storage blink:<PCIeSSD FQDD>
racadm storage unblink:<FQDD>
racadm storage unblink:<PCIeSSD FQDD>
NOTE
: The Start or Stop a Blink feature is not supported for HHHL PCIe SSD devices.
80 RACADM Subcommand Details