Reference Guide

NOTE:
The attribute racadm getconfig -g cfgractuning -o
cfgRacTuneChassisMgmtAtServer must be set as non-zero in CMC.
The attribute racadm get system.ChassisControl.ChassisManagementMonitoring
attribute must be enabled in iDRAC.
--proxy must be entered at the end of the command.
The root privilege is the default privilege for Local RACADM proxy.
The user privilege in the Remote RACADM proxy for CMC maps to iDRAC privilege.
Required CMC Privilege for an operation Required iDrac Privilege for proxy operation
CMC Login User Login
Chassis Conguration Administrator Congure
User Conguration Administrator Congure User
Clear Logs Administrator Logs
Chassis Control Administrator System Control
Server Administrator System Control
Test Alert User System Operations
Debug Command Administrator Debug
Fabric x Administrator (where x is A, B, or C) System Control
When CMC is not placed on the network, the import, export, and le operation commands to CIFS, NFS,
or FTP will fail.
When the Remote or Local RACADM Proxy operation is in progress, if the iDRAC is reset, then the Proxy
operation fails and the output is not displayed in Remote or Local RACADM.
When racadm getsystem.ChassisControl.ChassisManagementMonitoring attribute is set
to
monitor, all the users including root users can only view the attribute.
To congure, set the attribute to monitor and manage in CMC.
Input
-uSpecies the user name of the remote share that stores the catalog le.
-pSpecies the password of the remote share that stores the catalog le.
-rSpecies the iDRAC IP address connected to CMC.
Example
Local RACADM
racadm getractime --proxy
Remote RACADM
racadm getractime -u root -p xxx -r 192.168.0 getractime --proxy
racdump
Description
Provides a single command to get dump, status, and general iDRAC board information.
To run this subcommand, you must have the Debug permission.
General System/RAC Information
Coredump Information
Network Interface Statistics
62 RACADM Subcommand Details