Reference Guide

<Switch> <Model Name> <HW Version> <FW Version>
switch-1 MXL 10/40GbE X01 9-2(0-296)
switch-2 M8024-k 10GbE SW A00 5.0.1.3
switch-3 Dell PowerConnect M8024 X00
switch-4 Dell PowerConnect M8024 X00
switch-5 Dell PowerConnect M6348 X02
switch-6 Dell PowerConnect M6220 A01
hwinventory
Description Allows you to display or export current internal hardware inventory or shipped hardware inventory by device.
NOTE: iDRAC supports a maximum of 12 parallel sessions of hardware inventory.
Synopsis
racadm hwinventory
racadm hwinventory NIC|FC
racadm hwinventory <FQDD>
racadm hwinventory export -f <filename> -u <username> -p <password> -l <CIFS
or NFS share>
Input
<FQDD>Species the FQDD of the target device.
FQDD — NIC.Slot.1–2
-f — Exported Hardware Inventory lename.
-u — Username of the remote share to where the le must be exported. Specify user name in a domain as
domain/username
-p — Password for the remote share to where the le must be exported.
-l — Network share location to where the Hardware Inventory must be exported.
Examples
To get the list of NIC FQDDs, type the following command:
racadm hwinventory nic
NIC.Slot.2-1-1:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C2
PartitionCapable : 1
NIC.Slot.2-1-2:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C3
PartitionCapable : 2
NIC.Slot.2-1-3:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C4
PartitionCapable : 3
NIC.Slot.2-1-4:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C5
PartitionCapable : 4
To display the statistics for the NIC FQDD, type the following command:
$racadm hwinventory <NIC FQDD>
Total RDMA Packets Received: 0
Total RDMA Packets Transmitted: 0
48