Reference Guide
Storage.Controller
The objects in this group manage storage controller attributes. This group is indexed.
The following sections provide information about the objects in this group.
Storage.Controller.BackgroundInitializationRate (Read or
Write)
Description The Background Initialization (BGI) rate is the percentage of the system's resources dedicated to perform the
background initialization of a virtual disk after it is created.
Legal Values Values: 0–100
Default value 100
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency None
Storage.Controller.BatteryLearnMode (Read Only)
Description
Battery Learn Mode controls a RAID controller's Battery Learn Cycle.
Legal Values
• Automatic
• Warn
• Disabled
• Not Supported
Default value None
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency A battery must be present on the controller.
Storage.Controller.CheckConsistencyMode (Read or Write)
Description
Check Consistency feature is used to verify the accuracy of the redundant (parity) information.
Legal Values
• Normal
• Stop On Error
Default value Normal
Write Privilege Server Control
License Required iDRAC Express or iDRAC Enterprise
Dependency None
Database Objects With Get and Set Commands 455