Reference Guide

iDRAC.Telnet.Port (Read or Write)
Description
Species the port number for the iDRAC Telnet interface.
Legal Values
Integral values: 1–65535
Default Value
23
Write Privilege
Congure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Telnet.Timeout (Read or Write)
Description
Denes the Telnet idle timeout.
Legal Values
Integral values: 0–10800
Default Value
1800
Write Privilege
Congure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Time
The objects in this group enable you to manage time zone setting for iDRAC.
iDRAC.Time.DayLightOset (Read or Write)
Description
Species the daylight savings oset (in minutes) to use for the iDRAC Time.
Legal Values Integral values: 0 – 60
Default Value 0
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
296 Database Objects With Get and Set Commands