Reference Guide

1 — Enabled
Default Value Enabled
Write Privilege Congure iDRAC
License Required Not Applicable
Dependency None
System.ThermalCong
The objects in this group manage the thermal conguration.
System.ThermalCong.CriticalEventGenerationInterval (Read
or Write)
Description Indicates the time interval (in days) for critical events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.EventGenerationInterval (Read or
Write)
Description
Indicates the time interval (in days) for warning events to be generated.
Legal Values Integral Values: 0-365
Default Value 30
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.ThermalCong.FreshAirCompliantConguration (Read
Only)
Description
Indicates whether or not the system is congured to be fresh air compliant.
Legal Values
0 — Not Applicable
1 — Yes
2 — No
216 Database Objects With Get and Set Commands