Reference Guide

System.Power.Hotspare.Enable (Read or Write)
Description Enables hot-spare functionality for the primary PSU selection. For more information about hot-spare, see the
iDRAC User’s Guide available at www.dell.com/esmmanuals.
NOTE: This object is supported only for iDRAC on Rack and Tower servers.
Legal Values
0 — Disabled
1 — Enabled
Default Value 1 — Enabled
Write Privilege Congure iDRAC
License Required iDRAC Express or iDRAC Enterprise
Dependency None
System.Power.Hotspare.PrimaryPSU (Read or Write)
Description
Represents the primary PSU selection.
NOTE: This object is supported only for iDRAC on Rack and Tower servers.
Legal Values
1 — PSU1
2 — PSU2
5 — PSU1 and PSU3
10 — PSU2 and PSU4
Default Value Not Applicable
Write Privilege
Congure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency
None
System.Power.Max.Amps (Read Only)
Description
Species the device Peak Power Consumption since this value was last cleared.
Legal Values
Values: 1–65535.
Default Value
Current peak power consumption
Write Privilege Not Applicable
License Required
iDRAC Express or iDRAC Enterprise
Database Objects With Get and Set Commands 201