Reference Guide

System.Power
This group provides power management features for iDRAC.
The following section provides information about the objects in this group.
NOTE: For Dell PowerEdge FM120x4 server with more than one iDRAC, the power is received and shared from CMC. Hence, the
information about power and temperature for individual iDRACs are not displayed.
System.Power.Status (Read Only)
Description
Represents the device power state, either ON or OFF.
Legal Values
0 — Server is o
1 — Server is on.
Default Value
0 — Server is o
Write Privilege Not Applicable
License Required Not Applicable
Dependency Not Applicable
System.Power.ServerAllocation (Read Only)
Description
Indicates the power allocated to running blades. This value is displayed in both watts and BTU/h units.
Legal Values
0–7928
Default Value Not Applicable
Write Privilege Not Applicable
License Required Not Applicable
Dependency
None
System.Power.Avg.LastDay (Read Only)
Description
Indicates the average power value during the last day.
Legal Values
Values: 1–65535
Default Value
Average power value during the last day.
Write Privilege Not Applicable
License Required
iDRAC Express or iDRAC Enterprise
Database Objects With Get and Set Commands 195