Reference Guide
• NIC.GlobalBandwidthAllocation
• NIC.IscsiFirstTgtParams
• NIC.IscsiGenParams
• NIC.IscsiInitiatorParams
• NIC.IscsiSecondaryDeviceParams
• NIC.IscsiSecondTgtParams
• NIC.NICCong
• NIC.NICPartitioningCong
• NIC.VndrCongGroup
• Storage.Controller
• Storage.enclosure
• Storage.PhysicalDisk
• Storage.VirtualDisk
System.Backplane
The objects in this group manage the backplane.
System.Backplane.BackplaneBusMode (Read Only)
Description
Indicates the backplane Serial General Purpose Input or Output (SGPIO) mode.
Legal Values
• 0 — Unknown
• 1 — I2C
• 2 — SGPIO
Default Value 1 — I2C
Write Privilege
Congure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency None
System.ChassisControl
The objects in this group are applicable only to modular chassis such as Dell PowerEdge M1000e. To control the chassis related events, use
this group.
System.ChassisControl.ChassisManagementMonitoring (Read
or Write)
Description
Enables or disables the event forwarding from CMC.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default value 1 — Enabled
Database Objects With Get and Set Commands 187