setting allows you to monitor and manage the chassis even if the CMC is not on the network. On an FX2/FX2s CMC, ensure that the
Chassis Management at Server setting is set to Monitor or Manage and Monitor. While this feature is enabled, iDRAC also generates
Redsh notications for chassis events.
Conguring chassis management and monitoring using iDRAC
web interface
1 In iDRAC web interface, navigate to Overview > iDRAC Settings > CMC.
2 In this section, enable chassis management and monitoring from iDRAC.
Conguring chassis management and monitoring using iDRAC
RACADM
To enable chassis management and monitoring using RACADM, use the following command:
racadm set system.chassiscontrol.chassismanagementmonitoring Enabled
For more information about chassis management and monitoring, see the iDRAC User’s Guide available at dell.com/idracmanuals.