Users Guide

Table Of Contents
Table 9. Thermal Settings (continued)
Object Description Usage Example
command, it applies a fan
speed offset of Low (23%
PWM) over baseline fan
speed
racadm set
system.thermalsetti
ngs FanSpeedOffset
0
FanSpeedMaxOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for Max Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset to
set this value using index
value 3
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedMaxOffsetVa
l
This returns a value such
as 100. This means that
when you use the following
command, it applies a fan
speed offset of Max (meaning
full speed, 100% PWM).
Usually, this offset results in
fan speed increasing to full
speed.
racadm set
system.thermalsetti
ngs FanSpeedOffset
3
FanSpeedMediumOffsetV
al
Getting this variable reads
the fan speed offset value
in %PWM for Medium Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 2
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedMediumOffse
tVal
This returns a value such
as 47”. This means that
when you use the following
command, it applies a fan
speed offset of Medium (47%
PWM) over baseline fan
speed
racadm set
system.thermalsetti
ngs FanSpeedOffset
2
FanSpeedOffset
Using this object with
get command displays the
existing Fan Speed Offset
value.
Using this object with set
command allows setting
the required fan speed
offset value.
The index value decides
the offset that is applied
Values are:
0 Low Fan Speed
1 High Fan Speed
2 Medium Fan Speed
3 Max Fan Speed
255 None
To view the existing setting:
racadm get
system.thermalsetti
ngs.FanSpeedOffset
Setting up managed system and management station 55