Users Guide

Table Of Contents
Table 9. Thermal Settings (continued)
Object Description Usage Example
If a system does not
support a particular air
exhaust temperature limit,
then when you run the
following command:
racadm set
system.thermalsetti
ngs.AirExhaustTemp
0
The following error message is
displayed:
ERROR: RAC947:
Invalid object
value specified.
Make sure to specify the
value depending on the type
of object.
For more information, see
RACADM help.
To set the limit to the default
value:
racadm set
system.thermalsetti
ngs.AirExhaustTemp
255
FanSpeedHighOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for High Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 1.
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedHighOffsetV
al
A numerical value, for example
66, is returned. This value
indicates that when you use
the following command, it
applies a fan speed offset of
High (66% PWM) over the
baseline fan speed
racadm set
system.thermalsetti
ngs FanSpeedOffset
1
FanSpeedLowOffsetVal
Getting this variable reads
the fan speed offset value
in %PWM for Low Fan
Speed Offset setting.
This value depends on the
system.
Use FanSpeedOffset
object to set this value
using index value 0.
Values from 0-100
racadm get
system.thermalsetti
ngs
FanSpeedLowOffsetVa
l
This returns a value such
as 23”. This means that
when you use the following
54 Setting up managed system and management station