Reference Guide

Table Of Contents
The following command is an optimized and filtered version:
racadm storage get batteries --refkey RAID.Integrated.1-1 -o -p Name
Battery.Integrated.1:RAID.Integrated.1-1
Name = Battery
â—‹ To generate and view information about the inventory of virtual disks connected to the controller., run the following
command:
racadm storage get vdisks
Disk.Virtual.0:RAID.Integrated.1-1
The following command displays all virtual disk keys connected to the controllers:
racadm storage get vdisks --refkey RAID.Integrated.1-1
Disk.Virtual.0:RAID.Integrated.1-1
The following command is an optimized and filtered version:
racadm storage get vdisks -o -p DeviceDescription,OperationalState
Disk.Virtual.0:RAID.Integrated.1-1
DeviceDescription = Virtual Disk 0 on Integrated raid Controller 1
OperationalState = Not applicable
â—‹ To generate and view information about the inventory of virtual disks, run the following command:
racadm storage get vdisks -o
Disk.Virtual.2:RAID.Integrated.1-1
Status
Ok
DeviceDescription Virtual Disk 2 on Integrated RAID
Controller 1
Name OS
RollupStatus Ok
State Online
OperationalState Not applicable
Layout Raid-0
Size 278.88 GB
SpanDepth 1
AvailableProtocols SAS
MediaType HDD
RACADM Subcommand Details 91