Reference Guide

Table Of Contents
switch-4 Dell PowerConnect
M8024
X00
switch-5 Dell PowerConnect
M6348
X02
switch-6 Dell PowerConnect
M6220
A01
hwinventory
Description Allows you to display or export current internal hardware inventory or shipped hardware inventory by
device.
NOTE: iDRAC supports a maximum of 12 parallel sessions of hardware inventory.
Synopsis
racadm hwinventory
racadm hwinventory NIC|FC
racadm hwinventory <FQDD>
racadm hwinventory export -f <filename> -u <username> -p <password> -l
<CIFS or NFS share>
Input
<FQDD> Specifies the FQDD of the target device.
FQDD NIC.Slot.12
-f Exported Hardware Inventory filename.
-u Username of the remote share to where the file must be exported. Specify user name in a
domain as domain/username
-p Password for the remote share to where the file must be exported.
-l Network share location to where the Hardware Inventory must be exported.
Examples
To get the list of NIC FQDDs, type the following command:
racadm hwinventory nic
NIC.Slot.2-1-1:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C2
PartitionCapable : 1
NIC.Slot.2-1-2:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C3
PartitionCapable : 2
NIC.Slot.2-1-3:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C4
PartitionCapable : 3
NIC.Slot.2-1-4:Emulex OCe14102-U1-D - 00:90:FA:4C:FE:C5
PartitionCapable : 4
To display the statistics for the NIC FQDD, type the following command:
$racadm hwinventory <NIC FQDD>
Total RDMA Packets Received: 0
Total RDMA Packets Transmitted: 0
Total RDMA Bytes Transmitted: 0
Total RDMA Bytes Received: 0
RACADM Subcommand Details