Reference Guide

Table Of Contents
NOTE: If FIPS is enabled, you cannot perform any actions associated with the vFlash SD card, such as configuring the
vFlash SD card, exporting or backing up server profile to the vFlash, or importing server profile using vFlash.
iDRAC.Serial
The objects in this group provide configuration parameters for the serial interface of iDRAC.
NOTE: This is supported only for rack and tower systems.
iDRAC.Serial.BaudRate (Read or Write)
Description
Sets the Baud rate on the iDRAC serial port.
Legal Values
9600
19200
57600
115200
Default Value
115200
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Serial.Command (Read or Write)
Description
Specifies a serial command that is executed after the user logs in to the serial console interface.
Legal Values
String of up to 128 ASCII characters
Default Value Not Applicable
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.Serial.Enable (Read or Write)
Description
Enables or disables the iDRAC serial console interface.
Legal Values
0 Disabled
1 Enabled
Default Value
0 Disabled
Write Privilege
Configure iDRAC
268 Database Objects With Get and Set Commands