Reference Guide

Table Of Contents
iDRAC.OS-BMC.PTCapability (Read or Write)
Description
Operating System to iDRAC Pass Through Capability status.
Legal Values
0 Capable
1 Not Capable or Unknown
Default Value
Depends on the server capability.
Write Privilege
Configure iDRAC
License
Required
iDRAC Express or iDRAC Enterprise
Dependency
None
iDRAC.OS-BMC.PTMode (Read or Write)
Description
Enables the pass-through with shared LOM or USB.
NOTE: To enable the pass-through, make sure that iDRAC.OS-
BMC.AdminState is enabled.
Legal Values
0 Iom-p2p
1 usb-p2p
Default Value 0 Iom-p2p
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency None
iDRAC.OS-BMC.UsbNicIpAddress (Read or Write)
Description
Displays the USB NIC IP address.
Legal Values
Valid IPv4 address
Default Value
169.168.0
Write Privilege
Configure iDRAC
License Required
iDRAC Express or iDRAC Enterprise
Dependency None
iDRAC.Racadm
To manage Remote RACADM connection settings, use the object in this group.
Database Objects With Get and Set Commands
261