Users Guide
Object Description Usage Example
FanSpeedHighOffsetVa
l, and
FanSpeedMediumOffset
Val objects (dened earlier)
are the values at which the
osets are applied.
MFSMaximumLimit
Read Maximum limit for MFS
Values from 1 — 100 To display the highest value that
can be set using
MinimumFanSpeed option:
racadm get
system.thermalsettings.
MFSMaximumLimit
MFSMinimumLimit
Read Minimum limit for MFS
Values from 0 to
MFSMaximumLimit
Default is 255 (means None)
To display the lowest value that
can be set using
MinimumFanSpeed option.
racadm get
system.thermalsettings.
MFSMinimumLimit
MinimumFanSpeed
• Allows conguring the
Minimum Fan speed that is
required for the system to
operate.
• It denes the baseline (oor)
value for fan speed and
system allows fans to go
lower than this dened fan
speed value.
• This value is %PWM value
for fan speed.
Values from
MFSMinimumLimit to
MFSMaximumLimit
When get command reports 255,
it means user congured oset is
not applied.
To make sure that the system
minimum speed does not
decrease lower than 45% PWM
(45 must be a value between
MFSMinimumLimit to
MFSMaximumLimit):
racadm set
system.thermalsettings.
MinimumFanSpeed 45
ThermalProfile
• Allows you to specify the
Thermal Base Algorithm.
• Allows you to set the system
prole as required for thermal
behavior associated to the
prole.
Values:
• 0 — Auto
• 1 — Maximum performance
• 2 — Minimum Power
To view the existing thermal
prole setting:
racadm get
system.thermalsettings.
ThermalProfile
To set the thermal prole to
Maximum Performance:
racadm set
system.thermalsettings.
ThermalProfile 1
ThirdPartyPCIFanRespons
e
• Thermal overrides for third-
party PCI cards.
• Allows you to disable or
enable the default system
fan response for detected
third-party PCI cards.
• You can conrm the
presence of third-party PCI
card by viewing the message
ID PCI3018 in the Lifecycle
Controller log.
Values:
• 1 — Enabled
• 0 — Disabled
NOTE: The default value
is 1.
To disable any default fan speed
response set for a detected
third-party PCI card:
racadm set
system.thermalsettings.
ThirdPartyPCIFanRespons
e 0
Setting up managed system and management station 59